Seitenansicht 56
Installing In-Sight
®
5000 Series Vision Sensors
43
5.2.3 24VDC Breakout Connector and Cable Specifications
The 24VDC Breakout connector provides access to power, serial communications, trigger
and high-speed outputs. The Breakout cable is not terminated (
Table 5-8).
1. If hardware handshaking is required, an I/O Expansion module must be used.
Table 5-8: 24VDC Breakout Connector Cable Pin-Out
Pin# Signal Name Wire Color
1 Power, +24 VDC White/Green
2 Trigger + Green
3 Trigger - White/Orange
4 High-Speed Out 0 Blue
5 High-Speed Out 1 White/Blue
6
RS-232 Receive (RxD)
1
Orange
7
RS-232 Transmit (TxD)
1
White/Brown
8 Ground Brown
NOTE:
Unused bare wires can be clipped short or tied back using a tie made from non-conductive
material. Keep all bare wires separated from the +24VDC (White/Green) wire.